1 Condenser
2 Degassing tank
3 Drinking water outlet
4 Cooling water inlet
5
Filling tank with control components
6
PU insulation
7
Outlet pipe for separated solids
8
Cooling water return pipe
9
Cooling water discharge from condenser
10
Cooling water ring distribution, condenser inlet
11
Discharge gas connection
12
Burner
13
Combustion chamber with dual discharge gas heat exchanger
14
Torus ( internal tank)
Technical data:
Height: 2100mm
Width:
(diagonal) approx. 1410 mm
Weight:
approx. 320 kg (weight empty)
Output:
48-50 litres/h
Energy consumption:
approx. 28-40 kW/h
Primary energy:
Electric, fossil fuels (oil/gas burner), biomass/waste (multifuel burner), solar thermal in combination with one or more primary energy sources.
approx. 98-99°C
Operating pressure:
1 bar to max. 3 bar
Cooling water inlet temperature:
max. 50°C (min. 5°C)
Cooling water outlet temperature:
max. 80°C (min. 30°C)
Cooling water volume:
approx. 900-1500 litres/h
Condensate outlet temperature:
min. 30°C 50°C
Fluid:
Seawater, pond water, river water, brackish water, well water and subterranean water
|
|
|
|
|
|